Differential Pressure Gauge TC 700 

  • Differential Pressure Gauge TC 700

    with piston mechanism in stainless steel

    • Certificate DIN EN 10204 / 2.2
    • Also available in version with separating diaphragm
    Technical Characteristics
    Standard: 0-1,0 bar
    Pressure level: PN 100
    P perm.: 100 bar
    Measurement chamber: with pressure port, wetted CrNi-steel 1.4571 2x G 1/4 female thread, right and left at the side, opposing (EN 837-1/7.3)
    Measuring element: wetted parts, compression spring CrNi-steel 1.4310
    Magnetic piston: wetted, piston in CrNi-steel 1.4571, magnet in barium-ferrite
    Clock face: aluminium, white with black scale outside (bar)
    Overload-proof: choice of 100/250/400 bar, 1-sided also
    Permitted temperatures: surroundings -20 to +60° Celsius
    Measuring material: maximal +100° Celsius
    Medium: all gases acc. to DVGW worksheet G260/I
    Display: Zeiger plus Schleppzeiger
    Display scale: bar and PSI
    Display ranges: 0 – 0,4 bar / 0 – 6 PSI
    0 – 0,6 bar / 0 – 9 PSI
    0 – 1,0 bar / 0 – 14 PSI
    0 – 1,6 bar / 0 – 23 PSI
    0 – 2,5 bar / 0 – 36 PSI
    0 – 4,0 bar / 0 – 58 PSI
    0 – 6,0 bar / 0 – 87 PSI
    0 – 10 bar / 0 – 145 PSI
    Display exactness: +/- 3% from scale end value
    Weight: basic unit 220 g
    Material: wetted parts: stainless steel 1.4571
    Compression spring: stainless steel 1.4310
    Flow direction (+/-): eft/right, optional right/left when using the valve register, the flow direction at valve register is adjustable. Left/right as well as right/left
    Bypass and shut-off valves: contained in valve register
    Filter: fine filter, addable
    Electrical connection: reed contact addable as single changer (3-pole) or double changer (6-pole)
    Protection class: IP 54 (EN 60529/IEC 529)
    Prices
    Bitte kontaktieren Sie uns unter info@tecon-systemtechnik.de oder +4926196389744. Danke!
    Item Order No. Connection Price in €
    le/ri ri/le VR
    Differential pressure gauge 0 to 400 mbar (0 to 6 psi) DMTC00400 RL VR 188,00
    Differential pressure gauge 0 to 600 mbar (0 to 9 psi) DMTC00600 RL VR 188,00
    Differential pressure gauge 0 to 1.0 bar (0 to 14 psi) DMTC01000 RL VR 188,00
    Differential pressure gauge 0 to 1.6 bar (0 to 23 psi) DMTC01600 RL VR 188,00
    Differential pressure gauge 0 to 2.5 bar (0 to 36 psi) DMTC02500 RL VR 188,00
    Differential pressure gauge 0 to 4.0 bar (0 to 58 psi) DMTC04000 RL VR 188,00
    Differential pressure gauge 0 to 6.0 bar (0 to 87 psi) DMTC06000 RL VR 188,00
    Differential pressure gauge 0 to 10 bar (0 to 145 psi) DMTC10000 RL VR 188,00
    Reed contact (3-pole/Wibrox IP 54) single changeover DMTCRW1  RL 172,50
    Reed contact (6-pole/Wibrox IP 54) double changeover DMTCRW2  RL 214,20
    Fine filter differential pressure gauge type TC 700 DMTCFI 46,20
    Fixing bracket for stable mounting on the filter DMTCH 38,70
    Valve register with bypass and shut-off valves VR 92,40
    Sintered metal screw-in filter: (only when using the valve register) VREF 36,80
    Application

    Monitoring of differential pressures at filter units, traps etc. in the fields of gas, water & air supply.

    Design and function
    • Pressures p1 and p2 are present in (+) and (-) measuring material chambers, separated by a pressure-actuated magnetic piston.
    • Pressure difference causes axial movement (measurement path) for the piston, which presses against the measurement range spring.
    • A ring magnet fitted to the instrument display follows the magnet integrated into the piston so that every position of the piston is directly represented by the position of the pointer.
    • This constructional design enables a complete mechanical separation of measurement system and display and therefore preventing all forms of possible leakage.
    • Volume flow from (+) to (-) measuring material chamber is minimal due to the constructive design and plays no significant role in measurement.
    • It is recommended to install a fine filter in the (+) measuring material chamber for particle-contaminated measuring material.
    Schematic Diagram

    See illustration

    Installation

    At the sides are 2 connections G 1⁄4“ (female thread) with the labelling (+) and (-). The plus connection (+) is connected with the measurement lead for the higher pressure and minus (-) with the measurement lead for the lower pressure.

    Mounting

    Held in position by rigid pipework or via special mounting element for walls, i.e. gantries (filter/trap).

    Product additions

    1. With reed contact
    Connection diagram reed contacts: Switching point using adjustment spindle adjustable from outside in the range from 10% to 100% of the scale end value.

    Max. switching voltage: 30 VDC/VAC
    Max. switching power: 5 W
    Max. current strength: 0,5 A
    Switch-back voltage: 5% (from scale end value)
    1st contact: pre-warning (at approx. 75%)
    2nd contact: switch over (at ca. 100%)
    Weight: basic unit with reed contact 405 g


    2. With separating diaphragm
    Used where there is coarse contamination or for liquids such as water etc., where a piston leakage is undesirable.

    3. Mounting element
    Consisting of
    1 fixing plate
    2 hexagonal bolts M8 x 50 or 100
    2 spacer sleeves 30 or 80 mm
    2 cheese-head screws M4 x 10 mm

    4. Fine filter
    Fine filter in (+) connection addable (or integrated) (sinter filter)

    5. Valve refister / manifold
    Installation / manifold / valve refister:

    Differential pressure gauge type TC -700 can be delivered as a unit with a valve register (manifold). The valve register cannot be retro- fitted to the standard version. The valve register offers the following mounting advantages:

    1. Performing the minus connection is made at the rear side of the valve register. The plus connection can be made either at the left or at the right. This avoids crossing of the measurement leads and the positioning of special versions of the basic unit.
    2. Pressure compatibility between (+) and (-) via knurled screw (1) in the middle of the valve register (e.g. run-up, for checking the 0 display during operation).
    3. Using both of the screws (2) O-ring sealed valves can be closed. Differential pressure gauge type TC-700 can then be removed problem-free from the valve register (e.g. for checking, exchanging, etc.)
    4. The valve register (manifold) contains both valves i.e. block ball-valves, which are otherwise necessary for mounting.
    5. Additionally, a filter cartridge can be screwed into the valve register (manifold) to protect the measurement mechanism.
    6. Maximum operating pressure for the valve register (manifold): 102 bar

    Technical data:

    Pressure level: PN 100
    Valve register/manifold: steel, galvanized