Rotary Gas meter in HTB iM-RM 

  • Rotary Gas meter in HTB (GGG40)

    Series iM-RM

    TECHNICAL CHARACTERISTICS
    Approvals: MID: T10036 – 2014/32/EU, OILM R137, EN12480
    PTB: 7.131/06.16
    Gas types: natural gas, town gas, liquid gas (gas phase),
    inert gases, gas types acc. to DVGW 260/1
    Pressure levels:  PN 10 to PN 16
    Rangeability: 1:100, 1:160, in relation to the atmospheric
    conditions (EU-Standard: 1:20)
    Flow Range: 0,8 to 400 m³/h
    Accuracy: 0,2 Qmax to Qmax: ± 1% or better
    Qmin to 0,2 Qmax: ± 2% or better
    Temperature Range: -25°C to + 60°C
    Housing Material: GGG40 (HTB), 5 bar

     

    TECHNICAL DATA
    G-Rating Qmax Qmin Nominal diameter Overall length L
      [m³/h] [m³/h] D [mm] [mm]
    G16 25  0,8 DN 50 (2″) 171
    G25 40 0,65 DN 50 (2″) 171
    G40 65 0,65 DN 50 (2″) 171
    G65 100 0,65 DN 50 (2″) 171
    G100 160 1 DN 80 (3″) 171
    G100 160 1,6 DN 80 (3″) 241
    G160 250 1,6 DN 80 (3″) 241
    G100 160 2,5 DN 100 (4″) 241
    G160 250 2,5 DN 100 (4″) 241
    G250 400 2,5 DN 100 (4″) 241

     

    Prices
    Bitte kontaktieren Sie uns unter info@tecon-systemtechnik.de oder +4926196389744. Danke!
    Price
    auf Anfrage
  • Conversion of diaphragm gas meters to rotary gas meter series

    Ready-to-install, commissioned sets for converting

    • From single-tube meters with T-piece into rotary meters
    • From 2-pipe diaphragm gas meters with horizontal connections into rotary gas meters
    • From 2-pipe diaphragm gas meters with vertical connections into rotary gas meters/li>

    Important! For flanges DN65/ DN80, PN16, please indicate whether they have 4 or 8 holes!

    Technical characteristics
    The conversion kits comprise:
    • 2 pipe fittings, welded and tested for strength and leak tightness
    • Gaskets to the meter and to the existing connection flanges
    • Bolts for the meter and to the existing connection flanges
    Pressure rating: PN16/ 5 bar
    Material:
    • Pipe fitting: P250GH/ P235GH
    • Gaskets: Klingersil or comparable., others on request
    • Bolts: 5.6/ 5-2, others on request
    Stamping/ certificates
    • Pipe fitting:  DIN EN 10204 3.1 certification with stamping and verfication of strength and pressure test PN5
    • Bolts: with quality and manufacturer’s mark
    Prices
    Bitte kontaktieren Sie uns unter info@tecon-systemtechnik.de oder +4926196389744. Danke!

    The following information is required for assambling the conversion kits:

    • Design of the existing diaphragm gas meter (1-pipe/ 2-pipe horizontal or 2-pipe vertical)
    • DN, PN and dimension L1 of the existing connecting flanges
    • DN, PN and dimension L2 of the planned rotary gas meter
    • Specification the required RAL color (e.g. 1012 Lemon Yellow or 7035 Light Grey, etc.)

    Examples of common conversion kits:

    • 2-pipe DGM, vertical, DN65 (4-hole), PN16, L1=510 mm to RGM DN50, PN16, L2=150 mm
    • 2-pipe DGM, vertical, DN65 (4-hole), PN16, L1=510 mm to RGM DN50, PN16, L2=171 mm
    • 2-pipe DGM, vertical, DN80 (8-hole), PN16, L1=510 mm to RGM DN50, PN16, L2=240 mm/li>
    • 2-pipe DGM, vertical, DN80 (8-hole), PN16, L1=640 mm to RGM DN50, PN16, L2=240 mm
    • 2-pipe DGM, vertical, DN100, PN16, L1=710 mm to RGM DN80, PN16, L2=240 mm
    • 2-pipe DGM, vertical, DN100, PN16, L1=710 mm to RGM DN80, PN16, L2=171 mm
    • 2-pipe DGM, horizontal, DN65 (4-hole), PN16, L1=574 mm to RGM DN50, PN16, L2=150 mm
    • 2-pipe DGM, horizontal, DN65 (4-hole), PN16, L1=574 mm to RGM DN50, PN16, L2=171 mm
    • 2-pipe DGM, horizontal, DN80 (8-hole), PN16, L1=574 mm to RGM DN50, PN16, L2=150 mm
    • 2-pipe DGM, horizontal, DN80 (8-hole), PN16, L1=574 mm to RGM DN50, PN16, L2=171 mm
    • 2-pipe DGM, horizontal, DN80 (8-hole), PN16, L1=684 mm to RGM DN50, PN16, L2=150 mm
    • 2-pipe DGM, horizontal, DN80 (8-hole), PN16, L1=684 mm to RGM DN50, PN16, L2=171 mm
    • 2-pipe DGM, horizontal, DN100, PN16, L1=804 mm to RGM DN80, PN16, L2=171 mm
    • 2-pipe DGM, horizontal, DN100, PN16, L1=804 mm to RGM DN80, PN16, L2=240 mm
    • Single-pipe DGM, DN65 (4-hole), PN16, L1=344 mm to RGM DN50, PN16, L2=150 mm
    • Single-pipe DGM, DN65 (4-hole), PN16, L1=344 mm to RGM DN50, PN16, L2=171 mm
    • Single-pipe DGM, DN80 (8-hole), PN16, L1=384 mm to RGM DN50, PN16, L2=150 mm
    • Single-pipe DGM, DN80 (8-hole), PN16, L1=384 mm to RGM DN50, PN16, L2=171 mm
    • Single-pipe DGM, DN100, PN16, L1=434 mm to RGM DN80, PN16, L2=171 mm
    • Single-pipe DGM, DN100, PN16, L1=434 mm to RGM DN80, PN16, L2=240 mm
    What Price
    We can also offer suitable conversion kits for replacing turbine meters with rotary meters. on request
    The design of the required rotary meter is available on request. on request
    A suitable rotary meter can also be offered. on request