Overpressure Protection Valve 

  • Overpressure Protection Valve

    MPV – BP/AP

    • DVGW
    • With integrated needle valve
    • Inspection certificate DIN EN 10204 3.1
    Technical Characteristics
    Type BP with membrane measuring system: PN 16
    Setting ranges: 0,1 – 3,5 bar
    Type AP with piston measuring system: PN 100
    Setting ranges: 1,5 – 60 bar
    Option: also available without shut-off valve
    Medium: all gases acc. to DVGW worksheet G 260/I
    Material: steel, galvanized
    Connections: both sides G 1⁄2“ acc. to ISO 228 part 1 entry connection with male thread exit sleeve with female thread
    Special versions: with BETA-Micro -Test gas measure- ment connection (compatible with other measurement systems e. g. Mini-Mess)
    In general

    The overpressure protection device type MPV-BP/AP protects downstream pressure measuring devices against unwanted excessive pressure increases and/or overpressure. In the field of instrumentation, pressure and/or pressure peaks can appear due to a number of reasons, which can considerably exceed the measurement range of the manometer etc.

    Design and function

    Upstream needle valve
    Gas to be measure enters through a bore in the housing to the shut-off valve. This shut-off valve can close or protect the direction of measurement, e.g. when testing pressure or when exchanging the overpressure protection measuring device.

    Overpressure protection measuring device
    The gas to be measured passes out of the shut-off valve into the measu- ring element. As long as the measured pressure is lower than the pressure acting on the coil spring on the piston i.e. the membrane, the valve stays at thru-flow position, i.e. it lets the pressure on the downstream measuring system (manometer, pressure measurement cell etc.) through.
    Should the measured pressure become higher than the coiled spring pressure, then the valve is closed by the action of the piston and/or the membrane system. Access to the measuring device is interrupted and this protects against unwanted pressure increases.

    Prerequisites for problem-free function

    Problem-free function demands dirt and/or particle-free gas. The presence of dirt in any form damages the surface of O-ring gaskets. Problem-free function and/or closure of the valve is no longer guaranteed.

    Prices
    Bitte kontaktieren Sie uns unter info@tecon-systemtechnik.de oder +4926196389744. Danke!
    Item Item No. Price €
    Overpressure protection valve with piston measuring system
    Setting range 1.5 to 2.5 bar
    MSMPVAP3 107,10
    Overpressure protection valve with piston measuring system
    Setting range 2.5 to 8.0 bar
    MSMPVAP4 107,10
    Overpressure protection valve with piston measuring system
    Setting range 8,0 to 12,0 bar
    MSMPVAP5 107,10
    Overpressure protection valve with piston measuring system
    Setting range 12,0 to 60,0 bar
    MSMPVAP6 107,10
    Overpressure protection valve with membrane measuring system
    Setting range 0,1 to 0,15 bar
    MSMPVBP1 121,80
    Overpressure protection valve with membrane measuring system
    Setting range 0,12 to 0,4 bar
    MSMPVBP2 121,80
    Overpressure protection valve with membrane measuring system
    Setting range 0,2 to 0,6 bar
    MSMPVBP3 121,80
    Overpressure protection valve with membrane measuring system
    Setting range 0,4 to 1,5 bar
    MSMPVBP4 121,80
    Overpressure protection valve with membrane measuring system
    Setting range 1,0 to 3,5 bar
    MSMPVBP5 121,80
    Tension spring as individual part for own replacement
    Indicate spring number when ordering
    MSMPVFEDER 2,50
    Inspection certificate DIN EN 10204 3.1 APZ 18,00