Manometer - Burdon Tube - safety version 

  • Manometer Type Series RF 10D 10.2 – EN 837-1/S3

    – Bourdon tube – safety version –

    • Version for gas acc. to DVGW G 491
    • Certificate DIN EN 10204/2.2
    Technical Characteristics
    Class: 1,0
    Standard sizes: NG 100 mm and 160 mm
    Connection: G ½“ B below, SW 22
    Connecting port: stainless steel (1.4571)
    Display range: 0-1 to 0-400 bar
    Measurement system: stainless steel (1.4571)
    Overload protection: 1.3 x scale end value, temporary
    Housing: stainless steel (1.4301) with unbreakable partition wall and blow-out rear wall
    Viewing glass: multi-layer safety glass
    Bayonet ring: stainless steel (1.4301)
    Temperature range: -20 °C to +60 °C
    Temperature behavior: 0,3% per 10°C from scale end value
    Protection class: IP 65 (EN 60 529/IEC 529)

     

    Prices
    Bitte kontaktieren Sie uns unter info@tecon-systemtechnik.de oder +4926196389744. Danke!
    Display range bar Item No.
    NG 160
    Price
    0 – 1 MA16R10102025 261,10
    0 – 1,6 MA16R10102035 261,10
    0 – 2,5 MA16R10102045 261,10
    0 – 4 MA16R10102055 261,10
    0 – 6 MA16R10102065 261,10
    0 – 10 MA16R10102075 261,10
    0 – 16 MA16R10102085 261,10
    0 – 25 MA16R10102095 261,10
    0 – 40 MA16R10102105 261,10
    0 – 60 MA16R10102115 291,70
    0 – 100 MA16R10102125 291,70
    0 – 160 MA16R10102135 291,70
    0 – 250 MA16R10102145 291,70
    0 – 400 MA16R10102155 291,70
    Certificate DIN EN 10204 / 2.2 APZM4 18,00
    Display range bar Item No.
    NG 100
    Preis
    0 – 1 MA10R10102025 110,40
    0 – 1,6 MA10R10102035 110,40
    0 – 2,5 MA10R10102045 110,40
    0 – 4 MA10R10102055 110,40
    0 – 6 MA10R10102065 110,40
    0 – 10 MA10R10102075 110,40
    0 – 16 MA10R10102085 110,40
    0 – 25 MA10R10102095 110,40
    0 – 40 MA10R10102105 110,40
    0 – 60 MA10R10102115 126,70
    0 – 100 MA10R10102125 126,70
    0 – 160 MA10R10102135 126,70
    0 – 250 MA10R10102145 126,70
    0 – 400 MA10R10102155 126,70
    Certificate DIN EN 10204 / 2.2 APZM4 18,00

     

    Dimensions
    NG Dimensions (mm) Mass
    a b D1 D2 e G h+-1 SW (kg)
    100 24 57,5 101 100 17,5 G 1/2” B 87 22 0,65
    160 24 58 1) 161 160 17,5 G 1/2” B 118 22 1,301

     

    Special version possible
    Connection: 1/2” ; 3/8” NPT/BSP
    M 20 x 1,5
    eccentric rear side
    Throttle screws: 0,3 mm; 0,6 mm; 0,8 mm
    Special scales: PSI/bar; etc.
    Double scales: bar/Pa, Pa/PSI etc.

     

    DVGW worksheet G 941

    Deployed pressure gauges have to be designed and constructed in their individual compressive strength range in relation to their resistance to cope with the highest possible operating pressure. At locations in which 2.5-times scale end value can be exceeded, e.g. between gas pressure regulating unit and incoming pressure-resistant shut-off valve or in the bypass line, pressure-resistant units have to be deployed or special measures be taken against overloading, e.g. through an excess pressure protection device (see datasheet MPV) or through the use of a pressure gauge with higher scale end values.